
PMM MODULAR SERIES
FEATURES
High frequency and double conversion on-line technology
Advanced battery management
Lightining and surge protection, short circuit and
Advanced PFC technology, JU frame, rack-mounted overload protection and tower convertible
EPO function
Wide input voltage range
Fully digitized microprocessor control
Parallel redundancy
Multilingual LCD and LED display
EMl/RFI noise filter
Smart RS232 communication with monitoring software
Optional SNMP card slot

PMP SERIES
UPS 10 KVA TO 800 KVA
Three Phase Models
NEXT GENERATION
SLEEK & COMPACT
Features
Online double conversion
Online Double Conversion design helps to output a pure sine wave, which is immune from the ups input, so that the load can run steadily.
UPS transfers among different working mode without output interruption, thereby powering the load uninterruptedly.
High power factor
The output power factor up to 0.9 better matches the load.
The input power factor 0.98with filter helps to improve the efficiency, reduce the harmonic pollution to the Grid and lower the UPS running cost.
Optimized battery management
Intelligent battery management system and advanced battery auto float/ boost charge technology, reduces the frequency of battery maintenance, greatly improves the battery efficiency and extends battery life.
Battery discharge time prediction: the system will display the backup time of battery calculated by discharge current and voltage.
Battery self-test: battery is automatically tested at regular intervals.
Strong overload capability
110 %/ 125 %/ 150 % overload for 60min/10min/ 1min.
Power walk in
Specially designed power walk in function, in which rectifier of each unit in parallel system will be turned on in sequence at intervals to avoid the sudden load on the generator, thereby reducing the cost of the generator required.
Multi-protection
Self-diagnosis function will take place before start-up for safety.
Multi-protection: AC input under/ over voltage, overload, short-circuit, over current, over bus voltage, over temperature, fan failure, auxiliary power failure, battery under voltage, battery over charge and so on.
Full DSP control
Full DSP Control avoids the risks caused by analog devices failure and makes the control system more stable and reliable.
Wide input adaptability
The range of AC input voltage is (380V/ 400Vac/ 415Vac) (-25 %/ + 20 %), minimizing transfer to battery mode, thereby greatly prolonging the battery life.
Wide input frequency ranging from 45Hz to 65Hz, ensure stability of UPS while generator connected.
N + X parallel redundancy
N + X parallel redundant design, up to 6 units available, makes the configuration more flexible. Any unit in parallel system fails, the faulty one will automatically cut off the output, and the load will be powered by the remained units.
It is easy to configure the parallel system just by connecting the parallel cables and doing proper settings.
Non-fixed Master-Slave relationship:Among several UPS in parallel, the unit startup first is Master UPS, the others are Slave. The master and slave may be exchanged.
Generator mode
Set the maximum output power of the generator when a smaller one than needed is employed to extend the battery duration time. In this case, the load is supplied by both the generator and battery.
LBS synchronization
Synchronize the output of the two independent UPS systems (single unit or parallel) even when the two systems are operating on different modes (bypass/ inverter) or on battery.
EPO function
Aconcave red EPO button with transparent cover is embodied in the LCD control panel for emergency power off.
User-friendly network management
LCD and LED mimic diagram: real time operation parameters and status.
RS232 & RS485 communication ports: for local monitor with corresponding software, and MODBUS protocol is optional.
SNMP adaptor (optional): for remote monitor through network.
Dry Contacts for additional monitoring:
a) UPS on Inverter
b) Mains input failure
c) Remote EPO
d) Battery low voltage alaram
e) UPS fault
f) UPS alarm
g) UPS on battery
h) UPS on bypass
Note: d) — h) optional

PMS Series
UPS 5 KVA TO 40 KVA
Three Phase Models
FEATURES
High reliability design
Double Conversion on-line design, which
makes the output a pure sine wave source with tracking frequency, phase-lock and voltage regulation, noise suppression, and
without power fluctuation interference, providing the load with more comprehensive protection.
Zero transfer time of output, satisfies high standard power requirements of precisionequipment.
Modular design and dual-CPU control, high reliability and stability ensure the safe operation and high efficiency. High reliability during operation
Pure online static bypass technology, provides a strong protection against overload and fault.
Built-in manual maintenance bypass,
further improves the reliability of continuous operation.
Wide input range
The range of AC input voltage is 380V +
20%, thereby it reduce the battery using frequency and greatly extending the battery
life.
Wide input frequency range, ensure all
types of fuel generators connected work
stable.
ll. Optimization of high-performance battery
Adapt intelligent battery management
(ABM) technology, thus it extends battery life and reduces battery maintenance time
Advanced CC( Constant current) I CV(constant voltage) auto-conversion charging technology maximizes the activation of cells, thus it saves the charging time and extending the battery life.
Comprehensive and reliable protection
Self-diagnosis function before start-up,
avoid the risks that the failure may lead to.
The multi-protections such as overload,
short-circuits, over-temperature, battery under voltage, battery over-charge and so on greatly ensure the system stability and reliability.
Strong Redundancy/parallel ability
Some units can be directly connected in
parallel, increasing the scalability of the
system.
the parallel system can share a group of
backup battery
Non-fixed Master-Slave relationship: Among several UPS in parallel, the unit startup first is Master UPS, the others are Slave UPS. The master and slave can be
exchanged. If the inverter of one UPS fails, the UPS will automatically cut off the output, then the load will be powered by
remained UPS.
User-friendly network management
. LCD accurately displays the status of
operation and data for users. Communications with computer can be realized by RS232 with the corresponding monitoring software. The various parameters can be shown on the communication interface.
External SNMP adapter. The UPS with remote network management capability can provide real-time data for communication and management through a variety of network management systems.

Features
- IGBT Rectifier Design
- Advanced Digital Signal Processor (DSP) controlled transformerless design
- High Input Power Factor (>0.99)
- Low Input current Harmonics (THDi ~ 3%)
- High Efficiency (up to 93%)
- Wide Input Voltage Range (-60% +25%) based on percentage of load
- Generator compatible Operation
Platinum PPM Series
Uninterruptible Power Supply Systems
On-Line “Double Conversion” Technology DSP Controlled
IGBT Rectifier UPS
10 KVA to 400 KVA
3 Phase input/ 3 Phase output
- Intelligent battery management system extends the lifetime of batteries
- Built in Static and Manual Bypass
- Communication with computers and network systems with SNMP availability (Optional)
- Low installation and operating costs
- EPO (Emergency Power Off)
- Small foot print
- Capable of 8 times paralleling
- High Reliable Digital Systems

Features
IGBT Rectifier Design
Real Digital Signal Processor (DSP) controlled transformer design
High Input Power Factor PFC (>0.99)
Low Input current harmonics (THDi ~ 3%)
High Efficiency (up to 93%)
Wide Input Voltage Range (-60% +25%) based on percentage of load
Generator compatible Operation
Intelligent battery management system extends the lifetime of batteries
Static and Manual Bypass
Built in Galvanic isolation transformer
Communication with computers and network systems with SNMP availability (Optional)
Low installation and operating costs
EPO (Emergency Power Off)
Small Footprint
Capable of 8 times paralleling
High reliable digital systems
Platinum PPT Series
Uninterruptible Power Supply Systems
On-Line “Double Conversion” Technology DSP Controlled
IGBT Rectifier UPS with Inbuilt Transformer Design
10 KVA to 400 KVA
3 Phase input/ 3 Phase output
Built in Static and Manual Bypass
Communication with computers and network systems with SNMP availability (Optional)
Low installation and operating costs
EPO (Emergency Power Off)
Small foot print
Capable of 8 times paralleling
High Reliable Digital Systems
IGBT Rectifier Design
Advanced Digital Signal Processor (DSP) controlled transformerless design
High Input Power Factor (>0.99)
Low Input current Harmonics (THDi ~ 3%)
High Efficiency (up to 93%)
Wide Input Voltage Range (-60% +25%) based on percentage of load
Generator compatible Operation
Intelligent battery management system extends the lifetime of batteries

PTM SERIES
UPS 3 KVA TO 6 KVA
Single Phase Models
NEXT GENERATION
SLEEK & COMPACT
Features
High Reliability Design
Double Conversion on-line design, which makes the output a pure sine wave source with tracking frequency, phase-lock and voltage regulation, low distortion and without power fluctuation interference, providing the load with more comprehensive protection.
Strong Protection For Load
Built-in isolation transformer, strong anti interference ability, protection.
Battery Cold Start Function
The can be start directly by battery group when no utility access in, which meets the emergent needs of user. Strong cold start ability, which can do the cold start operation when full load.
Comprehensive and Reliable Protection
Self-diagnosis function before start-up avoid the risks that the failure may lead to.
The multi-protections such as overload, short-circuit, over-temperature, battery under voltage, battery over charge and so on greatly ensure the system stability and reliability.
Advanced phase-locked synchronization technology and dual electronic static out put switches, ensure the switching opertion between bypass and inverter without any disturbance. When UPS fails, it can transfer to bypass interruption provide AC power to load and provide the alarm information as well.
DC start function. The UPS can be started directly without AC, which meet the emergent needs of the user.
Wide Input Range
Wide input voltage range up to: 160-270Vac, avoid frequently switching to battery mode, which adapt to the areas with harsh environment.
Wide input frequency range, ensure all types of fuel generators connected work stable.
Optimization of High-Performance Battery
Adapt intelligent battery management (ABM) technology, thus extending battery life and reducing battery maintenance times.
Advanced floating switching and charging technology maximums the activation of the battery, thus saves the charging time and extends the battery life.
User-friendly network management
Communication with computer can be realized by RS232 with corresponding monitoring software. The various parameters can be shown on the communication interface.
SNMP adapter. The UPS with remote network management capability can provide real-time data for communication and
management systems.
UHF Digital Series
1 KVA TO 20 KVA
Single & Three Phase Input / Single Phase Output

DESCRIPTION:
POWER ONE UHF Series on line UPS systems IGBT inverter with advanced high frequency technology and maintaining pure and precise sine wave output and sophisticated DSP control and reliable.
FEATURES:
- Sleek and low foot print
- Sophisticated DSP based digital controlled Design
- True Sine Wave double conversion online topology
- Input Active Power factor is near unity.
- Wide Input range.
- Input Current Harmonic Suppression
- High efficiency design
- RS232 communication port and inbuilt SNMP slot.
- Enhanced protection against lightning surges, sag and swell.
- Hot Stand by facility for 1 to 20KVA
- PRS facility for 5 to 20KVA up to 3 times.
APPLICATIONS:
- Data Centre
- Computer Work Stations
- Net Working Equipments and EPBX
- Telecom and Cellular Equipments
- Automatic Teller Machines
- Medical Equipments
- Fire Protection Equipments
- Special Purpose Machines
- PLC and CNC Control Circuit.
- DSP Based Digital Controller
- TRUE Sine Wave
- Double Conversion Online
- Input Near Unity Power Factor
- Input Current Harmonic Suppression
- Sleek and Low Foot Print

APPLICATIONS:
- Data center
- Computer Work Stations
- Telecom and Cellular Equipments
- All Automatic data processing equipments
UHF Rack mounting Series
RATING: 1KVA, 2KVA, 3KVA, 6KVA,
7.5KVA & 10KVA 1P-1P
6KVA, 7.5KVA, 10KVA, 15KVA &
20KVA 3P-1P.
DESCRIPTION:
POWER ONE Rack Mounting Series on
line UPS systems IGBT inverter with
advanced high frequency technology and
maintaining pure and precise sine wave
output and sophisticated DSP control and
reliable.
FEATURES
- Sleek and low foot print
- Sophisticated DSP based digital controlled Design
- True Sine Wave double conversion online topology
- Input Active Power factor is near unity.
- Wide Input range.
- Input Current Harmonic Suppression
- High efficiency design
- RS232 communication port and inbuilt SNMP slot.
- Enhanced protection against lightning surges, sag and swell.
- Hot Stand by facility for 1 to 20KVA
- PRS facility for 5 to 20KVA up to 3 times.
- Touch to on switch
Why Choose Power-One?
- Varying Product Range
- Advanced Technology
- 25 Year Old Trusted and Valuable Enterprise
- Dedicated and Committed Management
- Handsome ROI (Return On Investment)