Product Catalogue:

Standard Specification:

PMM MODULAR SERIES

PMM MODULAR SERIES

FEATURES

High frequency and double conversion on-line technology

Advanced battery management

Lightining and surge protection, short circuit and

Advanced PFC technology, JU frame, rack-mounted overload protection and tower convertible

EPO function

Wide input voltage range

Fully digitized microprocessor control

Parallel redundancy

Multilingual LCD and LED display

EMl/RFI noise filter

Smart RS232 communication with monitoring software

Optional SNMP card slot

PMP SERIES

UPS 10 KVA TO 800 KVA

Three Phase Models

NEXT GENERATION
SLEEK & COMPACT

Features

Online double conversion

Online Double Conversion design helps to output a pure sine wave, which is immune from the ups input, so that the load can run steadily.

UPS transfers among different working mode without output interruption, thereby powering the load uninterruptedly.

High power factor

The output power factor up to 0.9 better matches the load.

The input power factor 0.98with filter helps to improve the efficiency, reduce the harmonic pollution to the Grid and lower the UPS running cost.

Optimized battery management

Intelligent battery management system and advanced battery auto float/ boost charge technology, reduces the frequency of battery maintenance, greatly improves the battery efficiency and extends battery life.

Battery discharge time prediction: the system will display the backup time of battery calculated by discharge current and voltage.

Battery self-test: battery is automatically tested at regular intervals.

Strong overload capability

110 %/ 125 %/ 150 % overload for 60min/10min/ 1min.

Power walk in

Specially designed power walk in function, in which rectifier of each unit in parallel system will be turned on in sequence at intervals to avoid the sudden load on the generator, thereby reducing the cost of the generator required.

Multi-protection

Self-diagnosis function will take place before start-up for safety.

Multi-protection: AC input under/ over voltage, overload, short-circuit, over current, over bus voltage, over temperature, fan failure, auxiliary power failure, battery under voltage, battery over charge and so on.

Full DSP control

Full DSP Control avoids the risks caused by analog devices failure and makes the control system more stable and reliable.

Wide input adaptability

The range of AC input voltage is (380V/ 400Vac/ 415Vac) (-25 %/ + 20 %), minimizing transfer to battery mode, thereby greatly prolonging the battery life.

Wide input frequency ranging from 45Hz to 65Hz, ensure stability of UPS while generator connected.

N + X parallel redundancy

N + X parallel redundant design, up to 6 units available, makes the configuration more flexible. Any unit in parallel system fails, the faulty one will automatically cut off the output, and the load will be powered by the remained units.

It is easy to configure the parallel system just by connecting the parallel cables and doing proper settings.

Non-fixed Master-Slave relationship:Among several UPS in parallel, the unit startup first is Master UPS, the others are Slave. The master and slave may be exchanged.

Generator mode

Set the maximum output power of the generator when a smaller one than needed is employed to extend the battery duration time. In this case, the load is supplied by both the generator and battery.

LBS synchronization

Synchronize the output of the two independent UPS systems (single unit or parallel) even when the two systems are operating on different modes (bypass/ inverter) or on battery.

EPO function

Aconcave red EPO button with transparent cover is embodied in the LCD control panel for emergency power off.

User-friendly network management

LCD and LED mimic diagram: real time operation parameters and status.

RS232 & RS485 communication ports: for local monitor with corresponding software, and MODBUS protocol is optional.

SNMP adaptor (optional): for remote monitor through network.

Dry Contacts for additional monitoring:
a) UPS on Inverter
b) Mains input failure
c) Remote EPO
d) Battery low voltage alaram
e) UPS fault
f) UPS alarm
g) UPS on battery
h) UPS on bypass
Note: d) — h) optional

Product Catalogue:

Standard Specification:

PMP SERIES

Customize Specification:

PMP SERIES

Product Catalogue:

Standard Specification:

PMS SERIES

Customize Specification:

PMS SERIES

PMS Series

UPS 5 KVA TO 40 KVA

Three Phase Models

FEATURES

High reliability design

Double Conversion on-line design, which
makes the output a pure sine wave source with tracking frequency, phase-lock and voltage regulation, noise suppression, and
without power fluctuation interference, providing the load with more comprehensive protection.

Zero transfer time of output, satisfies high standard power requirements of precisionequipment.

Modular design and dual-CPU control, high reliability and stability ensure the safe operation and high efficiency. High reliability during operation

Pure online static bypass technology, provides a strong protection against overload and fault.

Built-in manual maintenance bypass,
further improves the reliability of continuous operation.

Wide input range

The range of AC input voltage is 380V +
20%, thereby it reduce the battery using frequency and greatly extending the battery
life.

Wide input frequency range, ensure all
types of fuel generators connected work
stable.
ll. Optimization of high-performance battery

Adapt intelligent battery management
(ABM) technology, thus it extends battery life and reduces battery maintenance time

Advanced CC( Constant current) I CV(constant voltage) auto-conversion charging technology maximizes the activation of cells, thus it saves the charging time and extending the battery life.

Comprehensive and reliable protection

Self-diagnosis function before start-up,
avoid the risks that the failure may lead to.

The multi-protections such as overload,
short-circuits, over-temperature, battery under voltage, battery over-charge and so on greatly ensure the system stability and reliability.

Strong Redundancy/parallel ability

Some units can be directly connected in
parallel, increasing the scalability of the
system.

the parallel system can share a group of
backup battery

Non-fixed Master-Slave relationship: Among several UPS in parallel, the unit startup first is Master UPS, the others are Slave UPS. The master and slave can be
exchanged. If the inverter of one UPS fails, the UPS will automatically cut off the output, then the load will be powered by
remained UPS.

User-friendly network management
. LCD accurately displays the status of
operation and data for users. Communications with computer can be realized by RS232 with the corresponding monitoring software. The various parameters can be shown on the communication interface.

External SNMP adapter. The UPS with remote network management capability can provide real-time data for communication and management through a variety of network management systems.

Features

  • IGBT Rectifier Design
  • Advanced Digital Signal Processor (DSP) controlled transformerless design
  • High Input Power Factor (>0.99)
  • Low Input current Harmonics (THDi ~ 3%)
  • High Efficiency (up to 93%)
  • Wide Input Voltage Range (-60% +25%) based on percentage of load
  • Generator compatible Operation

Product Catalogue:

Standard Specification:

PPM SERIES

Customize Specification:

PPM SERIES

Platinum PPM Series

Uninterruptible Power Supply Systems

On-Line “Double Conversion” Technology DSP Controlled

IGBT Rectifier UPS
10 KVA to 400 KVA

3 Phase input/ 3 Phase output

  • Intelligent battery management system extends the lifetime of batteries
  • Built in Static and Manual Bypass
  • Communication with computers and network systems with SNMP availability (Optional)
  • Low installation and operating costs
  • EPO (Emergency Power Off)
  • Small foot print
  • Capable of 8 times paralleling
  • High Reliable Digital Systems

Features

IGBT Rectifier Design

Real Digital Signal Processor (DSP) controlled transformer design

High Input Power Factor PFC (>0.99)

Low Input current harmonics (THDi ~ 3%)

High Efficiency (up to 93%)

Wide Input Voltage Range (-60% +25%) based on percentage of load

Generator compatible Operation

Intelligent battery management system extends the lifetime of batteries

Static and Manual Bypass

Built in Galvanic isolation transformer

Communication with computers and network systems with SNMP availability (Optional)

Low installation and operating costs

EPO (Emergency Power Off)

Small Footprint

Capable of 8 times paralleling

High reliable digital systems

Product Catalogue:

Standard Specification:

PPT SERIES

Customize Specification:

PPT SERIES

Platinum PPT Series

Uninterruptible Power Supply Systems

On-Line “Double Conversion” Technology DSP Controlled

IGBT Rectifier UPS with Inbuilt Transformer Design

10 KVA to 400 KVA

3 Phase input/ 3 Phase output

Built in Static and Manual Bypass

Communication with computers and network systems with SNMP availability (Optional)

Low installation and operating costs

EPO (Emergency Power Off)

Small foot print

Capable of 8 times paralleling

High Reliable Digital Systems

IGBT Rectifier Design

Advanced Digital Signal Processor (DSP) controlled transformerless design

High Input Power Factor (>0.99)

Low Input current Harmonics (THDi ~ 3%)

High Efficiency (up to 93%)

Wide Input Voltage Range (-60% +25%) based on percentage of load

Generator compatible Operation

Intelligent battery management system extends the lifetime of batteries

PTM SERIES

UPS 3 KVA TO 6 KVA

Single Phase Models

NEXT GENERATION
SLEEK & COMPACT

Features

High Reliability Design

Double Conversion on-line design, which makes the output a pure sine wave source with tracking frequency, phase-lock and voltage regulation, low distortion and without power fluctuation interference, providing the load with more comprehensive protection.

Strong Protection For Load

Built-in isolation transformer, strong anti interference ability, protection.

Battery Cold Start Function

The can be start directly by battery group when no utility access in, which meets the emergent needs of user. Strong cold start ability, which can do the cold start operation when full load.

Comprehensive and Reliable Protection

Self-diagnosis function before start-up avoid the risks that the failure may lead to.

The multi-protections such as overload, short-circuit, over-temperature, battery under voltage, battery over charge and so on greatly ensure the system stability and reliability.

Advanced phase-locked synchronization technology and dual electronic static out put switches, ensure the switching opertion between bypass and inverter without any disturbance. When UPS fails, it can transfer to bypass interruption provide AC power to load and provide the alarm information as well.

DC start function. The UPS can be started directly without AC, which meet the emergent needs of the user.

Wide Input Range

Wide input voltage range up to: 160-270Vac, avoid frequently switching to battery mode, which adapt to the areas with harsh environment.

Wide input frequency range, ensure all types of fuel generators connected work stable.

Optimization of High-Performance Battery

Adapt intelligent battery management (ABM) technology, thus extending battery life and reducing battery maintenance times.

Advanced floating switching and charging technology maximums the activation of the battery, thus saves the charging time and extends the battery life.

User-friendly network management

Communication with computer can be realized by RS232 with corresponding monitoring software. The various parameters can be shown on the communication interface.

SNMP adapter. The UPS with remote network management capability can provide real-time data for communication and
management systems.

Product Catalogue:

Standard Specification:

PTM SERIES

Customize Specification::

PTM SERIES

UHF Digital Series

1 KVA TO 20 KVA

Single &  Three Phase Input / Single Phase Output


DESCRIPTION:
POWER ONE UHF Series on line UPS systems IGBT inverter with advanced high frequency technology and maintaining pure and precise sine wave output and sophisticated DSP control and reliable.

FEATURES:

  • Sleek and low foot print
  • Sophisticated DSP based digital controlled Design
  • True Sine Wave double conversion online topology
  • Input Active Power factor is near unity.
  • Wide Input range.
  • Input Current Harmonic Suppression
  • High efficiency design
  • RS232 communication port and inbuilt SNMP slot.
  • Enhanced protection against lightning surges, sag and swell.
  • Hot Stand by facility for 1 to 20KVA
  • PRS facility for 5 to 20KVA up to 3 times.

APPLICATIONS:

  • Data Centre
  • Computer Work Stations
  • Net Working Equipments and EPBX
  • Telecom and Cellular Equipments
  • Automatic Teller Machines
  • Medical Equipments
  • Fire Protection Equipments
  • Special Purpose Machines
  • PLC and CNC Control Circuit.
  • DSP Based Digital Controller
  • TRUE Sine Wave
  • Double Conversion Online
  • Input Near Unity Power Factor
  • Input Current Harmonic Suppression
  • Sleek and Low Foot Print

Product Catalogue:

Standard Specification:
UHF Digital Series

Customize Series:
UHF Digital Series

APPLICATIONS:

  • Data center
  • Computer Work Stations
  • Telecom and Cellular Equipments
  • All Automatic data processing equipments

UHF Rack mounting Series

RATING: 1KVA, 2KVA, 3KVA, 6KVA,
7.5KVA & 10KVA 1P-1P
6KVA, 7.5KVA, 10KVA, 15KVA &
20KVA 3P-1P.

DESCRIPTION:
POWER ONE Rack Mounting Series on
line UPS systems IGBT inverter with
advanced high frequency technology and
maintaining pure and precise sine wave
output and sophisticated DSP control and
reliable.

FEATURES

  • Sleek and low foot print
  • Sophisticated DSP based digital controlled Design
  • True Sine Wave double conversion online topology
  • Input Active Power factor is near unity.
  • Wide Input range.
  • Input Current Harmonic Suppression
  • High efficiency design
  • RS232 communication port and inbuilt SNMP slot.
  • Enhanced protection against lightning surges, sag and swell.
  • Hot Stand by facility for 1 to 20KVA
  • PRS facility for 5 to 20KVA up to 3 times.
  • Touch to on switch

Why Choose Power-One?

  • Varying Product Range
  • Advanced Technology
  • 25 Year Old Trusted and Valuable Enterprise
  • Dedicated and Committed Management
  • Handsome ROI (Return On Investment)